call-us
Muffle Furnace 1400 Degree C

Muffle Furnace 1400 Degree C

100000 INR/Piece

Product Details:

  • Type Muffle Furnace 1400 Degree C
  • Weight 10-20 Kilograms (kg)
  • Width 5-10 Millimeter (mm)
  • Material Mild Steel
  • Application For Hospital Use
  • Click to View more
X

Muffle Furnace 1400 Degree C Price And Quantity

  • 100000 INR/Piece
  • 1 Piece

Muffle Furnace 1400 Degree C Product Specifications

  • Mild Steel
  • For Hospital Use
  • Muffle Furnace 1400 Degree C
  • 10-20 Kilograms (kg)
  • 5-10 Millimeter (mm)

Muffle Furnace 1400 Degree C Trade Information

  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • 7 Piece Per Week
  • 1 Week
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Asia, Central America, Africa
  • All India

Product Description

  • Specially designed to suit the requirement of various field like education ,metallurgical magnets and material testing laboratory
  • Housing made of heavy gauge M.S duly finished in epoxy powder coated shade
  • High grade silica boards and layers of ceramic insulation provided to minimize the heat loss.
  • Silicon carbide heating elements provided in refractory type heating chamber for superb temperature I uniformity.
  • The temperature is being controlled by microprocessor based auto tuning temperature controller having digital  indicator
  • The control panel consist main temp. controller (SCR power controller )MCB,HRC fuse etc. and mounded at one side of the  unit
  • Optional programmable controller with thyristor for soft start 

Cat. No. 

Size chamber

L X W X D

Heaters watts

Max.Temp.

Working temp.

Volts

AEI -131/ A

6,LX6,WX12,D

4.0 K.W.

1400 C

1350 C

230 Volts

AEI -131/ B

9,LX9,WX18,D

6.0 K.W.

1400 C

1350 C

440 Volts

AEI -131/ C

12,LX12,WX1,D

17.0K.W.

1400 C

1350 C

440 Volts



Reliable High-Temperature Performance

Engineered for consistent operation at temperatures up to 1400C, this muffle furnace is tailored for demanding hospital applications. Its dependable heating element and robust mild steel construction ensure long-term usability and safety, fulfilling rigorous laboratory standards.


Versatile Application in Hospitals

The furnace accommodates samples 5-10 mm wide, making it suitable for multiple hospital laboratory processes, including sterilization, ashing, and heat treatment. Its compact weight and size enable easy installation and relocation within medical and research facilities across India.

FAQ's of Muffle Furnace 1400 Degree C:


Q: How is the Muffle Furnace 1400 Degree C typically used in hospital laboratories?

A: This furnace is primarily used for ashing, sterilization, and heat treatment processes in hospital laboratories. Its high temperature allows for efficient material testing, sterilization of instruments, and preparation of samples for research or diagnostic analysis.

Q: What are the benefits of using a muffle furnace with a 1400C temperature capacity?

A: A 1400C muffle furnace provides precise temperature control for high-temperature treatments, resulting in accurate experimental outcomes. Its robust design ensures safety and longevity, making it suitable for repeated use in demanding hospital environments.

Q: When should the Muffle Furnace 1400 Degree C be selected over other types of furnaces?

A: This furnace should be chosen when your hospital laboratory requires precise and consistent heating at temperatures up to 1400C, especially for processes involving small samples (5-10 mm in width) that demand controlled and contaminant-free environments.

Q: Where is the Muffle Furnace 1400 Degree C distributed and supplied in India?

A: The furnace is distributed, exported, manufactured, supplied, and traded throughout India by authorized dealers and reputable suppliers, ensuring accessibility and local support for hospitals and laboratories across the country.

Q: What materials are used in the construction of this muffle furnace?

A: The furnace is constructed from durable mild steel, providing the necessary strength and thermal stability to withstand repeated high-temperature cycles while maintaining structural integrity in medical laboratory settings.

Q: What is the process for operating the Muffle Furnace 1400 Degree C safely?

A: To operate safely, users should place samples within the furnace chamber, set the desired temperature, and monitor the process using provided controls. Adequate ventilation and safety gear are essential due to high operating temperatures. Follow the manufacturer's instructions for optimal performance and longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Scientific Instruments' category



Back to top
trade india member
AJANTA EXPORT INDUSTRIES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.