Product Details:

  • Instruments Type Critical care equipment
  • Frequency 50/60 Hz
  • Measurement Range 0-360 Joules (defibrillation energy)
  • Features ECG monitoring, charging indicator, built-in recorder
  • Display Type LCD display
  • Storage Instructions Store in a dry and cool environment
  • Accuracy Meets medical device standards
  • Click to View more
X

Zoll PD 2000 Defibrillator Price And Quantity

  • 15000 INR/Piece
  • 1 Piece
  • Selectable, 2 to 360 Joules
  • 3-lead or paddles
  • 0C to 40C
  • Meets AAMI DF-2 and IEC standards
  • Adult/paediatric paddles supported
  • Adult paddles, ECG cable, power cord, user manual
  • Internal battery, 2 hours typical
  • Less than 5 seconds to maximum energy
  • Event storage capability
  • Synchronous and asynchronous modes
  • Audio and visual alarms
  • English (others optional with software upgrade)
  • Yes
  • Integrated strip recorder

Zoll PD 2000 Defibrillator Product Specifications

  • Critical care equipment
  • No
  • 5-7 Kilograms (kg)
  • Approx 320 x 270 x 180 mm
  • Biphasic waveform
  • Defibrillator
  • Automatic/Manual
  • Low
  • 50/60 Hz
  • Yes
  • 0-360 Joules (defibrillation energy)
  • ECG monitoring, charging indicator, built-in recorder
  • LCD display
  • White and Grey
  • Store in a dry and cool environment
  • Yes
  • 100-240 V AC, 50/60 Hz
  • Plastic
  • Meets medical device standards
  • Approx. 50 VA
  • Manual
  • Cardiac resuscitation, advanced life support
  • New
  • Hospital and Emergency
  • Defibrillation and ECG monitoring
  • Selectable, 2 to 360 Joules
  • 3-lead or paddles
  • 0C to 40C
  • Meets AAMI DF-2 and IEC standards
  • Adult/paediatric paddles supported
  • Adult paddles, ECG cable, power cord, user manual
  • Internal battery, 2 hours typical
  • Less than 5 seconds to maximum energy
  • Event storage capability
  • Synchronous and asynchronous modes
  • Audio and visual alarms
  • English (others optional with software upgrade)
  • Yes
  • Integrated strip recorder

Zoll PD 2000 Defibrillator Trade Information

  • Cheque, Telegraphic Transfer (T/T), Cash in Advance (CID), Cash Advance (CA)
  • 1 Piece Per Week
  • 1 Week
  • Western Europe, Asia, Australia, North America, Eastern Europe, Middle East, South America, Central America, Africa
  • All India

Product Description

 Zoll PD 2000 Defibrillator

AJANTA EXPORT INDUSTRIES  are manufacturer, supplier and Exporter of  Zoll PD 2000.The ZOLL PD 2000 Advisory Defibrillator/Pacemaker is the first device designed as a completely integrated system for early defibrillation and advanced cardiac life support in the hospital. The built-in ventricular fibrillation detection system eliminates adapters and a "paddle free" electrode system is easily applied to speed shock delivery and external pacing. Standardized controls make it ideal for the hospital planning implementation of early defibrillation to improve outcomes from cardiac arrest. This small and lightweight unit is the most versatile hospital defibrillation system available today. The PD 2000 is equally suited for general floor use by noncritical care BLS trained staff and ACLS code teams for defibrillation, external pacing and transport. New state-of-the-art modular AC power and rapid battery recharging allow the PD 2000 to meet the needs of every hospital area. Its easily exchangeable low cost lead acid battery system provides unequaled crash-cart up time and improved quality in device maintenance and readiness. No other unit provides a hospital with the inherent flexibility of the ZOLL PD 2000 Advisory Defibrillator/Pacemaker.

Features:

Innovative features:
 

Large Monitor

Non-fade monitor

ECG monitor

Strip recorder

AC power supply for stationary use

 

Specifications:


Type: VVI demand; asynchronous (fixed rate)

when used without ECG leads

Pulse Type: Rectilinear, constant current

Pulse Duration: 40 milliseconds.

Pulse Amplitude: Variable to 140 mA

Pacing Rate: Variable from 30 to 180 PPM

Output Protection: Fully defibrillator-protected and isolated

Pacer On: Message display on monitor

Defibrillator

Waveform: Damped sinusoid

Output Energy

Delivered: Selectable at 2, 3, 5, 7, 10, 20, 30, 50,100, 150, 200, 300, 360 joules

Charge Time: Less than 10 seconds

Delivered Energy

Display: CRT monitor displays delivered energy

Synchronized Mode: Synchronizes defibrillator pulse to patients R-wave. SYNC message

displayed on monitor. Marker on monitor and on recorder paper identifies R-wave

Internal Paddles: Output limited to 50 joules when internal paddles are connected. Discharge from paddles

Charge Controls: Control on apex paddle and front panel.

Paddles: Standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles

Defibrillation Electrodes: Specifically designed ZOLL Multi- Function Electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs

Integral Defibrillator Tester: Integral circuitry allows complete test

of defibrillator charge and discharge without removing paddles from storage wells. Identical circuitry allows complete test of unit configured with multifunction cable

Defib On: Message display on monitor

Monitor and Display

Patient Connection: Via 3-lead ECG cable, paddles, and elec trodes. Selectable by front panel switch

Input Protection: Fully defibrillator-protected. Special circuit prevents distortion of ECG by pacer pulse

Bandwidth: .5 40 Hz (3dB) standard

Display Format: Nonfade, moving trace with freeze capability

Monitor On: Message display on monitor

Screen Type: High-resolution CRT display

Screen Size: 5 inches diagonally (108 mm x 85 mm viewing area)

 



Advanced Energy Selectivity and Safety

The PD 2000 offers selectable defibrillation energy from 2 to 360 Joules, suitable for both adults and children. Its biphasic waveform ensures effective cardiac resuscitation with less risk of injury. Integrated audio and visual alarms provide instant alerts, maximizing safety during emergencies.


Versatile Monitoring and Recording

Equipped with a clear LCD display and 3-lead or paddle ECG monitoring, the PD 2000 allows real-time heart rhythm analysis. The built-in strip recorder documents events, supporting comprehensive patient care and post-event review. Data storage capabilities allow for easy access to event histories.


Portability and Rapid Response

Weighing just 5-7 kg and operating reliably across 0C to 40C, this defibrillator is highly portable and suitable for use in challenging hospital and emergency environments. It charges to maximum energy in less than 5 seconds and provides up to 2 hours of operation on its internal battery.

FAQ's of Zoll PD 2000 Defibrillator:


Q: How is the defibrillation energy adjusted on the Zoll PD 2000 Defibrillator?

A: The energy level can be easily selected between 2 and 360 Joules using the device's controls, ensuring tailored therapy for adults or pediatric patients. The selection can be done prior to defibrillation to match the specific resuscitation protocol.

Q: What benefits does the integrated ECG monitoring and strip recorder offer?

A: The integrated LCD display and 3-lead ECG or paddle monitoring provide real-time cardiac rhythm analysis, while the strip recorder documents each event, facilitating immediate decision-making and comprehensive record keeping for patient care and review.

Q: When should the internal battery be checked or replaced?

A: It is recommended to check the battery status regularly as part of routine equipment checks. The typical battery provides 2 hours of continuous operation; replace the battery according to manufacturer's guidelines or when standby time decreases noticeably.

Q: Where can the Zoll PD 2000 Defibrillator be most effectively used?

A: This device is designed primarily for hospitals and emergency settings. Its portability, robust construction, and ability to operate under a range of temperatures make it well-suited for ambulances, critical care units, and other demanding healthcare environments.

Q: What process should be followed if an alarm sounds during use?

A: If an audio or visual alarm is triggered, promptly check the device display and follow the indicated prompts. The alarms indicate critical parameters such as energy selection errors, lead disconnects, or operational issues that require attention before proceeding.

Q: How does the PD 2000 support both manual and automatic operation?

A: The defibrillator can be operated manually by healthcare professionals or set to automatic mode, adjusting processes such as energy selection and charging. This dual functionality ensures flexibility for various clinical situations and user preferences.

Q: What is the advantage of the synchronous and asynchronous modes?

A: Synchronous mode allows the defibrillator to deliver shocks in synchronization with the cardiac cycle, crucial for certain arrhythmias. Asynchronous mode enables immediate shock delivery irrespective of the heart rhythm, ensuring prompt action during cardiac arrest.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Electrical Defibrillator' category



Back to top
trade india member
AJANTA EXPORT INDUSTRIES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.