Product Description
Seriological Water Bath
True to Ps name, BSE Serological Water Baths are versatile enough to handle any clinical procedure. Inactivation, Agglutination, as well as well as most serology. Pharmaceutic. Mo medical procedure First time in India.
BSE serological Water bath have unmatched Performance and and quality raw material used.
Specifications:
Constructions:BSE Serological Water Baths are sturdy, with Double walled construction. Complete inner chamber made of Highly polished stainless steel. Outer chamber is made of Mild Steel Sheet, finished with power coated paint Gap Between the walls is filled with special grade glass wool for proper insulation to avoid heat losses
The Water Bath is provided with a drain plug to facilitate easy emptying and cleaning of the inner chamber whenever necessary. Test tube racks can be provided on requirement Pyramidal shaped cover and perforated removable diffuser are standards accessories
Heating elements:Immersion heating elements made of high grade material are fitted at bottom with different ratings for different sizes
Temperature Control:Temperature is generally controlled by "IMPORTED" Capillary type thermostat from ambient to 80°C±0.5°C Temperature control knob
Control Panel:The equipment is provided with a panel having a thermostat control knob, ON OFF switch, two pi at lamps. Supplied WO- cord and plug
Power Requirement:Suitable to operate on 220 v, single phase, 50 Hz, AC supp
Optional Accessories:
Test Tube Rack made of Stainless Steel 3 Tier with LA ting Handle 13 mm Dia 24 Hole cc 16 mm Die 18 Hole
Digital Display temp. Indicator in lieu of Thermometer
Digital Display temp. Controller-cum-indicator in lieu of thermostat & thermometer
Microprocessor based PID temperature controller cum indicator in lieu of thermostat & thermometer
Stirrer With 1/20 hp motor with S.S rod & blades
Size of Inner chamber:
| W | H | D |
| 330 x 250 x 150 mm for 4 racks 1 kw |
| 330 x 300 x 150 mm for 4 racks 1.5 kw |
| 455 x 300 x 150 mm for 6 racks 2 kw |
| 605 x 300 x 150 mm for 8 racks 3 kw |
| 250 x 125 X 125 mm With lid 0.5 kw |
Uniform Precision in Laboratory ProcessesBuilt for demanding laboratory conditions, this water bath maintains steady temperatures for sensitive procedures. Its digital controller enables users to adjust and view the current temperature, delivering high accuracy and repeatability. The immersion heating element, combined with high-grade insulation, ensures uniform heat distribution-a critical aspect for cell cultures and precise serological testing.
Sturdy Stainless Steel DesignThe inner chamber and lid are constructed from rust-resistant stainless steel with a mirror-polished finish, supporting easy cleaning and hygiene with durability. The exterior, made of powder-coated mild steel, reinforces strength against regular laboratory use. The removable perforated diffuser tray and gabled lid cater to ease-of-use and facilitate different sample handling scenarios.
Comprehensive Safety and User BenefitsA built-in over-temperature cut-off protects delicate samples and equipment, providing peace of mind during extended incubations. The design supports convenient removable trays and easy operation, while digital temperature control assures accurate settings. Its portable size, moderate heating capacity, and versatile application make it a dependable choice for labs in India and beyond.
FAQ's of Seriological Water Bath:
Q: How is the temperature controlled and monitored in this seriological water bath?
A: The serological water bath uses a digital temperature controller and a capillary thermostat to maintain and display temperatures accurately from 5C above ambient up to 100C. The display allows easy real-time monitoring, and the system achieves a control accuracy of 0.5C at 60C.
Q: What makes this water bath suitable for serological tests and tissue culture applications?
A: Its consistent temperature control, uniform heating through a removable perforated tray, and over-temperature safety features ensure that sensitive samples are incubated under optimal conditions, making it ideal for serological and tissue culture work in laboratories.
Q: Where can this equipment be installed and who are the main users?
A: This equipment is designed for laboratory settings in hospitals, research institutes, and universities. It is widely used by biologists, medical technologists, and laboratory technicians for sample incubation and precise temperature-dependent testing.
Q: When should the perforated diffuser tray be removed or cleaned?
A: The removable perforated diffuser tray should be taken out for cleaning after each use or whenever changing sample types. Regular cleaning ensures sterility and prevents cross-contamination between experiments.
Q: What is the benefit of the gabled stainless steel cover in this water bath?
A: The gabled stainless steel lid minimizes heat and moisture loss during operation, contributing to temperature stability and preventing water evaporation. It also minimizes contamination risk, supporting sterile laboratory conditions.
Q: How does the over-temperature cut-off safeguard my samples?
A: The over-temperature cut-off feature automatically shuts off the heater if the bath temperature exceeds the preset safety limit. This prevents overheating, protecting both samples and equipment from potential damage.
Q: What process should be followed to set up and use the water bath for the first time?
A: To set up, place the unit on a stable, dry, and level surface. Fill the stainless steel chamber with water upto the recommended level, insert the tray if required, set the temperature on the digital controller, and allow the bath to reach equilibrium. Always use the lid during operation, and ensure routine maintenance for longevity.