call-us
Microcontroller pH Meter

Microcontroller pH Meter

8500 INR/Piece

Product Details:

  • Control Type Microcontroller Based
  • Power Supply AC Mains
  • Shape Rectangular
  • Display Type Digital LCD Display
  • Features Automatic Temperature Compensation, Auto Buffer Recognition, Calibration Memory
  • Temperature Resistance 0C to 100C
  • Accuracy 0.01 pH
  • Click to View more
X

Microcontroller pH Meter Price And Quantity

  • 8500 INR/Piece
  • 1 Piece
  • Automatic or Manual (0°C to 100°C)
  • >10^12 Ohms
  • Large, Easy-to-Read LCD
  • Sturdy, Chemical-Resistant Casing
  • Approx. 1.2 kg
  • Available
  • 0.01 pH
  • BNC / Universal Socket
  • 1 Second
  • 0 to 14 pH
  • Automatic, 2 or 3 Point
  • 5°C to 45°C
  • <80% RH (Non-condensing)

Microcontroller pH Meter Product Specifications

  • 10 W
  • Microcontroller Based
  • 220-440 Volt (v)
  • Microcontroller
  • pH Meter
  • 220 x 180 x 85 mm
  • AC Mains
  • Plastic / ABS
  • For Hospital and Laboratory Use
  • ABS Body
  • Digital Microcontroller Based
  • Digital LCD Display
  • Rectangular
  • 5-7 Kilograms (kg)
  • pH Sensitive Electrode Glass
  • 0.01 pH
  • pH Measurement in Laboratory, Industrial, and Educational Purposes
  • Automatic Temperature Compensation, Auto Buffer Recognition, Calibration Memory
  • 0C to 100C
  • Automatic or Manual (0°C to 100°C)
  • >10^12 Ohms
  • Large, Easy-to-Read LCD
  • Sturdy, Chemical-Resistant Casing
  • Approx. 1.2 kg
  • Available
  • 0.01 pH
  • BNC / Universal Socket
  • 1 Second
  • 0 to 14 pH
  • Automatic, 2 or 3 Point
  • 5°C to 45°C
  • <80% RH (Non-condensing)

Microcontroller pH Meter Trade Information

  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • 7 Piece Per Day
  • 1 Week
  • North America, Eastern Europe, Central America, Middle East, South America, Western Europe, Asia, Australia, Africa
  • All India

Product Description

 Microcontroller pH Meter

AJANTA EXPORT INDUSTRIES are manufacturer, supplier and Exporter of  pH & Temperature Meter

Technical Specifications :

Range

0 TO 14 pH

Resolution            

0.01 pH

Accuracy              

+ 0.01 pH + 1 digit

Slope Adjustment

80 % to 120 % by default 100 %.

Temp. Compensation

0 to 100 º C  Auto with temp. probe/Manual with Keys.

Auto Buffer Recognition

4.00 pH, 7.00pH, 9.20 pH (AUTOMATIC)

Calibration

AUTO & MANUAL, 3 Point/2 Point (Programmable)

2- POINT, 3- POINT

mV (ORP)

Range

- 1999  mV to  + 1999 mV

Resolution

1 mV

Accuracy               

+ 01%  +  1 digit

Temperature

Range

-50.0 TO +200 ºC

Resolution

0.1 ºC

Accuracy

+ 0.1 % of range + 1 digit

Input Type

Pt 100 probe

Data Entry

By Six soft touch keys with audible sound

Storage

1000 Samples

Real time display

24 Hour mode with Date

Interface               

RS 232 & Parallel

Print Format

All Data & Date Wise (Programmable)

Digital Output

Serial RS 232 & Printer Centronics (Programmable)



Exceptional Precision and Versatility

Engineered for both accuracy and ease, this digital microcontroller pH meter supports automatic or manual calibration at two or three points, ensuring precise readings across a wide range of pH values. Ideal for applications in laboratories, hospitals, and industries, the instrument's robust performance and high input impedance guarantee dependable measurements every time.


Designed for User Convenience

The meter's large, clear LCD display, fast one-second sampling rate, and data hold function make daily testing straightforward. With rugged, chemical-resistant ABS construction and a secure BNC/universal electrode connection, users benefit from a reliable device that stands up to harsh laboratory environments and frequent use.

FAQ's of Microcontroller pH Meter:


Q: How do I calibrate the microcontroller pH meter?

A: Calibration of this pH meter is automatic, supporting both 2-point and 3-point calibration methods. Simply follow the prompts on the display when immersing the electrode in standard buffer solutions, and the instrument will guide you through the calibration process.

Q: What applications can this pH meter be used for?

A: This pH meter is suitable for laboratory research, hospital diagnostics, industrial quality control, and educational demonstrations. Its wide measuring range and high accuracy meet rigorous scientific and industrial standards.

Q: Where should I install and store this pH meter?

A: The meter operates ideally at temperatures between 5C and 45C and should be stored in environments with humidity below 80% RH (non-condensing). Keep the device on a stable, clean surface in laboratories, clinics, or industrial sites away from corrosive fumes and direct sunlight.

Q: What is the benefit of automatic temperature compensation in this meter?

A: Automatic temperature compensation ensures that pH measurements remain accurate regardless of temperature variations in your samples, enhancing reliability and simplifying the testing process in dynamic environments.

Q: How do I use the data hold function on this pH meter?

A: The data hold function allows you to freeze the current reading on the display, making it easy to record or review pH values without losing accuracy during fast-paced operations.

Q: What type of electrodes are compatible with this instrument?

A: The pH meter utilizes a pH-sensitive glass electrode and accommodates a variety of electrodes via its BNC or universal socket connection for maximum flexibility in sample analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top
trade india member
AJANTA EXPORT INDUSTRIES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.