Product Description
Harpenden Skinfold Caliper
AJANTA EXPORT INDUSTRIES are manufacturer, supplier and exporter Harpenden Skinfold Caliper.
The Harpenden Skinfold Caliper is a precision instrument designed for use in the performance of Skinfold thickness measurements (from which estimates of body fat are derived). The use of this instrument has been well established and documented over the past 40 years.
Designed in 1958 in collaboration with D. J. M. Tanner, a prominent force in the use of Skinfold measurements in the derivation of body fat measurement,
The Harpenden Skinfold Caliper has been used all over the world on projects of international importance and is the most prestigious Caliper available.
It is the only Caliper CE marked under the Medical Devices Directive 93/42/EEC for a Class 1 Device with Measuring Function and is calibrated using masters traceable to National Standards.
Dial Graduation: 0,20 mm
Measuring Range: 0 mm to 80 mm
Measuring Pressure: 10 gms/mm2 (constant over range)
Accuracy: 99.00%
Repeatability: 0,20 mm
Precision Engineered for ConsistencyThe Harpenden Skinfold Caliper features a precisely calibrated mechanism with consistent pressure application, delivering accurate body fat or skinfold thickness measurements every time. Its 0.2 mm accuracy and robust steel frame make it suitable for repeated use in clinical and athletic settings. The analog dial enhances readability, ensuring dependable assessment for practitioners.
Corrosion-resistant Design with User-friendly FeaturesCrafted from stainless steel and finished with a polished, corrosion-resistant surface, this caliper is built to withstand frequent handling. The ergonomic, rectangular shape and lightweight structure add comfort during use. The instrument is supplied with a protective carry case and an instructional manual for safe storage and guidance, making it ideal for busy professionals.
FAQ's of Harpenden Skinfold Caliper:
Q: How is the Harpenden Skinfold Caliper used for body fat measurement?
A: To use the Harpenden Skinfold Caliper, grasp the selected skinfold using your thumb and forefinger, then apply the caliper jaws perpendicularly at the marked site. Release the trigger to let the jaws apply constant pressure (10 gms/mm2) and take the reading indicated on the analog dial. Repeat for multiple sites as required by assessment protocols.
Q: What are the key features that ensure measurement accuracy and reliability?
A: The caliper offers precision calibration, a fine 1 mm graduation, a constant pressure mechanism, and an accuracy of 0.2 mm. Its robust stainless steel construction and polished finish ensure both durability and long-term alignment for repeated, consistent measurements.
Q: When should the Harpenden Skinfold Caliper be calibrated or serviced?
A: The caliper is factory-calibrated and, due to its durable design, typically requires little maintenance. However, for optimal accuracy, it should be checked periodically, especially in high-use settings such as medical clinics, sports facilities, or during regular fitness assessments.
Q: Where can the Harpenden Skinfold Caliper be used effectively?
A: This instrument is suitable for medical facilities, physiotherapy centers, sports science labs, and fitness assessments across a variety of settings. Its portability and protective case also allow for convenient use during fieldwork or on-site evaluations.
Q: What is included with the Harpenden Skinfold Caliper upon purchase?
A: Each Harpenden Skinfold Caliper comes with a hard black carry case for protection, an instructional user manual for reference, and is securely packaged to minimize damage during transportation.
Q: How does the caliper benefit health and fitness professionals?
A: Healthcare, sports, and fitness professionals benefit from the caliper's precision and reliability for monitoring client or patient progress over time, helping tailor interventions or track changes in body fat composition for improved outcomes.