Product Description
ProductDescription
We havemarked a distinct and dynamic position in the market by providing ahigh-quality array of Regular Double Beam Spectrophotometer.
ProductSpecification
| Wavelength Range | 190-1100 nm, 190nm -1100nm |
| Type | Non Portable |
| Model | Aei-Dp-Rt122 |
| Application | Laboratory Use |
| Brand | AjantaExports |
| Band width | 1 nm |
| Data Output Port | USB |
| Lamps | D2 Lamp & Tungston Lamp |
| Photometric Range | -0.3 - 3.0 Abs |
| Path Length | 10 mm |
| Baseline Flatness | 0.001A |
| Cell Holder | 8 cell holder |
| Detector | Silicon Photovoltaic |
| Dimension | 590X460X220mm |
| Display | Graphic LCD (320*240 dots) |
| Drift | Less than =+/0.0004A bs/h |
| Interface | USB Port and parallel port (Printer) |
| Keyboard | Membrane Keyboard |
| Light source | Deuterium & Tungsten lamp |
| Noise | 0.0003A/H |
| Optical System | Double Beam,Grating 1200lines/mm |
| Photometeric Mode | A,T,C |
| Photometric Display Range | -3A3A |
| Photometric Repeatability | 0.001 ABS |
| Photometric accuracy | 0.3%T(0-100%T) |
| Power | AC220V/50Hz or AC 110V/60Hz |
| Price | 2850 USD |
| Scanning Speed | Fast/Medium/Low |
| Spectral Bandwidth | 1nm |
| Stability | 0.0004 A/H500nm |
| Stray light | Less than =0.02%T |
| Wavelength Resoluution | 0.1nm |
| Wavelength Setting | Auto |
| Wavelength accuracy | +/- 0.3 nm |
| Wavelength repeatabiliy | 0.2nm |
| Weight | 25kg |
| Minimum Order Quantity | 1 Piece |
Advanced Double Beam Optics for Precise MeasurementsThis spectrophotometer utilizes double beam optics, which provides superior accuracy by automatically compensating for lamp fluctuations and optical variations. The automatic eight-cell sample holder facilitates batch experiments, increasing efficiency and data reliability in clinical, biochemical, and pharmaceutical laboratories.
User-Friendly Microprocessor and ConnectivityMicroprocessor control streamlines operation with automatic wavelength settings and onboard data storage. The large LCD graphic display ensures clear visualization of results, while USB and RS-232C ports allow easy software integration, enabling comprehensive UV-Vis spectroscopic analysis and data export to Windows-based computers.
Versatility and Robust ConstructionDesigned for laboratory environments, the device operates reliably in temperatures from 10C to 50C. The combination of stainless steel (shell) and optical glass (cells) ensures durability and optimal performance. Its compact form (550 x 450 x 220 mm) suits diverse laboratory spaces, while bundled accessories support immediate setup and usage.
FAQ's of Double beam microprocessor uv-vis spectrophotometer regular model with softwere eight cell holder:
Q: How does the double beam design enhance spectrophotometric accuracy?
A: The double beam optical system measures the sample and reference simultaneously, compensating for fluctuations in lamp intensity and environmental conditions. This design provides more reliable and accurate absorbance readings, particularly important in precise quantitative and qualitative analyses.
Q: What is the process for using the automatic 8-cell sample holder?
A: The spectrophotometer's automatic sample holder accommodates up to eight cells, enabling sequential measurement. Users load their samples into the holder, and the microprocessor-controlled system automatically moves between cells, streamlining multi-sample analysis without manual intervention.
Q: When should I perform baseline correction, and how is it ensured?
A: Baseline correction should be carried out at the start of analysis sessions. This model achieves excellent baseline flatness (0.001A from 200-1100 nm) and uses advanced electronics to deliver consistently accurate spectra, reducing manual baseline adjustment needs.
Q: Where can the data from measurements be exported or analyzed?
A: All measurement results and spectra can be exported via USB or RS-232C interface to Windows-compatible software. The bundled software supports advanced data analysis, including spectrum, kinetics, and report generation, making integration with laboratory information systems seamless.
Q: What types of light sources does the instrument use for UV and visible measurements?
A: The spectrophotometer utilizes a Deuterium lamp for ultraviolet measurements and a Tungsten Halogen lamp for the visible range, ensuring full wavelength coverage from 190 to 1100 nm for a broad range of analytical needs.
Q: How user-friendly is the operation for laboratory personnel?
A: Operation is simplified through automatic wavelength setting, microprocessor-controlled functions, and a large LCD graphic display, allowing even less-experienced users to perform accurate analyses and batch measurements efficiently.
Q: What are the primary benefits of using this model in clinical or pharmaceutical labs?
A: This model offers precise quantitative and qualitative analysis, robust stability (0.002A/h at 500 nm), efficient multi-sample handling, and compatibility with modern software-all crucial for demanding environments such as clinical diagnostics and pharmaceutical quality control.