call-us
Biosafety Cabinet Class Ii, B2

Biosafety Cabinet Class Ii, B2

90000 INR/Piece

Product Details:

  • Function Biological safety containment, Protection level: Personnel, Product, Environment
  • Instruments Type Laboratory Safety Cabinet
  • Storage Instructions Store in clean, dry, well-ventilated room, covered when not in use
  • Features Microprocessor controller, LCD display, UV Light, Interlock system, Exhaust system, Negative pressure airflow, Energy saving mode
  • Display Type Digital/LCD
  • Usage Type Laboratory, Hospital, Research, Pharma
  • Frequency 50/60 Hz
  • Click to View more
X

Biosafety Cabinet Class Ii, B2 Price And Quantity

  • 90000.00 - 95000.00 INR/Piece
  • 5 Piece
  • 90000 INR/Piece

Biosafety Cabinet Class Ii, B2 Product Specifications

  • Less than 65 dB(A)
  • 220-240 V AC, 50/60 Hz
  • Digital/LCD
  • New
  • Laboratory, Hospital, Research, Pharma
  • 50/60 Hz
  • Yes
  • Microprocessor controller, LCD display, UV Light, Interlock system, Exhaust system, Negative pressure airflow, Energy saving mode
  • No
  • White/Grey (standard lab color)
  • Electric
  • Biosafety Cabinet Class II, B2
  • Customizable/1200 x 700 x 2100 mm (example)
  • Biological containment for laboratory samples, personnel, and environment
  • Store in clean, dry, well-ventilated room, covered when not in use
  • 400-750 W (varies by model size)
  • Biological safety containment, Protection level: Personnel, Product, Environment
  • Stainless Steel 304 (internal work chamber), Powder-coated steel (external body)
  • No
  • Approx. 180-250 kg (varies by configuration)
  • HEPA Filtration, Airflow containment (100% exhausted)
  • Laboratory Safety Cabinet
  • Automatic/Microprocessor Controlled

Biosafety Cabinet Class Ii, B2 Trade Information

  • AMBALA
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash Advance (CA), Paypal, Cash in Advance (CID), Cheque
  • 10000 Piece Per Week
  • 7 Days
  • Yes
  • If order is confirmed we will reimburse the sample cost
  • Western Europe, Australia, North America, South America, Eastern Europe, Middle East, Central America, Asia, Africa
  • All India
  • ISO , CE , FDA , WHO-GMP, ROHS

Product Description

Biosafety Cabinet
  • Biosafety Biological Safety Cabinet Class Ii Re-circulates 70% of Air Through Hepa Filter & 30% Exhaust
  • Biosafety Cabinet is Used to Protect Personnel, Product and the Environment From Exposure to Biohazards and Cross Contamination During Routine Procedures.
  • Used for Various Applications in the Life Science, Clinical, Pharmaceutical and Industrial Laboratory.
These Cabinets Are Designed to Provide 3 Basic Types of Protection.
  • Personnel Protection From Harmful Agents Inside the Cabinet.
  • Product Protection to Avoid Contamination of the Work, Experiment or Process.
  • Environment Protection
Salient Features & Construction of Biosafety Cabinet
  • Low Cost.
  • Low Noise.
  • User Friendly Ergonomic Design.
  • Controlled Environment Particulate Free Product Protection.
  • Work Area Surrounded by Negative Pressure, Double Wall Plenums for Protection.
  • Aerodynamic Designed Airflow Grille Maintains Safety by Preventing Blockage.
  • Silent Vibration
  • Free Blower Ensure Noiseless Operation.
  • Sound Level No More Than 65 Dba.
  • The Unit is Suitable for Class 100 Conditions.
  • 70% of the Air is Re-circulated Through the Hepa Filter.
  • The Contaminated Air is Drawn by the Blower Through the Plenum of the Cabinet.
  • 30% of the Air is Exhausted From Work Area.
  • Filtered Exhaust - Protects Ambient Environment, and Avoids Build Up, Air Borne Particles.
  • The Exhaust of Safety Cabinet is Connected to the Virus Burn Out Unit for Product and Personnel Protection.
  • Air is Drawn Through Pre-filter and is Made to Pass Through High Effective Hepa (High Efficiency Particular Air) Filters.
  • The Efficiency of Hepa Filter is Greater Than 99.97% Down to 0.3 Micron.

Basic Material is Thick Board Wood Front Back Top and Exterior Surfaces Are Covered With Formica. Or Cold Rolled Steel Duly Powder Coated or Stainless Steel (Ss-304) (as Ordered).
  • Working Table is Made of Stainless Steel Sheet (Ss-304 Grade).
  • Window Opens to 20cm±5mm Working Height With Predefined Locking Device.
  • Built in U.v. Germicidal Light
  • Facilitates Sterilization of Working Area Before and After Use. Cock - for Gas, Air or Vacuum, (Only 1 No.) is Provided.
  • Working Area is Illuminated by Fluorescent Lighting Fitted to the Unit.
  • The Blower and Motor Assembly is Statically and Dynamically Balanced of 1/5 H.p. Capacity Operates With Minimum Noise Level.
  • Height of the Working Table Provides Comfortable "Sit Down" Working Position for the Operator.
  • Supplied Complete With Cord & Plug to Work on Single Phase 220 / 230 Volts a.c. Supply.
  • With Digital Timer for Uv Light Blower & Oil Based Manometer


Unmatched Safety and Containment

Engineered for advanced containment, Class II Type B2 Biosafety Cabinets utilize complete exhaust systems, ensuring no air recirculation and incorporating high-efficiency HEPA filtration. This guarantees thorough protection of personnel, product, and work environment from biological hazards. Negative pressure airflow and seamless stainless steel work surfaces further enhance safety and maintain sterile conditions.


Efficient and User-Friendly Operation

The microprocessor-controlled system automates airflow management and safety alarms for instant response to failures. The cabinets LCD interface, energy-saving mode, splash-proof electrical outlets, and easy-to-clean surfaces provide convenience while meeting stringent compliance standards. Dedicated exhaust and customizable sizes adapt to diverse laboratory and research applications across India.

FAQs of Biosafety Cabinet Class Ii, B2:


Q: How does the Class II Type B2 Biosafety Cabinet ensure biological containment?

A: This cabinet achieves biological containment by using complete air exhaustion through a dedicated ducting system, combined with vertical laminar airflow and advanced HEPA filtration (99.99% efficiency at 0.3 microns). Negative pressure airflow prevents contaminant escape, safeguarding personnel, products, and the environment within laboratory, hospital, and research settings.

Q: What are the unique features included in this model for user safety and convenience?

A: Key safety features include a tempered safety glass sash, seamless spill-retaining stainless steel work surface, microprocessor-controlled visual and audio airflow/filter alarms, interlock systems, and an LCD interface. For convenience, the cabinet offers internal splash-proof sockets, caster wheels with leveling feet, service valves for gas/vacuum/air, and dual lighting (fluorescent and UV germicidal lamps).

Q: When should the HEPA filter be replaced and how is filter performance monitored?

A: HEPA filters should be inspected and replaced according to the manufacturers recommended intervals or when prompted by airflow or filter failure alarms. The cabinets automatic monitoring system continuously checks filter status and alerts users to performance issues via visual and audio signals displayed on the LCD panel.

Q: Where should the Biosafety Cabinet Class II B2 be installed for optimal performance?

A: For optimal performance, install the cabinet in a clean, dry, well-ventilated room with access to dedicated exhaust ducting. Ensure clearance for airflow and maintenance, and keep it covered when not in use to preserve internal sterility. It is not wall-mounted, so place it on a stable, level floor surface away from traffic to minimize contamination risk.

Q: What is the process for cleaning and maintaining the cabinet?

A: Routine cleaning involves wiping down interior stainless steel surfaces with suitable disinfectants, washing the pre-filter regularly, and periodically checking service valves and caster wheels. Maintenance includes verifying filter condition, airflow velocities, and alarm functionality using the microprocessor controller and ensuring the exhaust system remains unobstructed.

Q: How is the Class II B2 cabinet beneficial for laboratory professionals?

A: The cabinet provides a controlled environment that offers triple protectionsafeguarding personnel, samples, and surroundings from biological contamination. Its automatic controls, compliance certification (NSF 49/EN 12469), efficient filtration, and robust exhaust system enhance operational safety and reliability, making it ideal for laboratories, hospitals, pharmaceutical, and research institutions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail