Product Details:

  • Temperature Resistance Up to 50C
  • Shape Rectangular
  • Control Type Microcontroller Based
  • Heating Capacity No Heating - Ambient Operation
  • Glass Type Standard Laboratory Glassware
  • Power Supply AC Mains
  • Speed Range Stirring Speed Adjustable (Up to 1200 rpm)
  • Click to View more
X

Auto Karl Fischer Titrimeter Price And Quantity

  • 1 Piece
  • 65000 INR/Piece
  • 0.01% to 100% Water Content
  • Volumetric and Coulometric
  • ISO 9001:2015
  • 0.01 ml
  • Liquid, Powder, Solid
  • Platinum Electrodes
  • RS 232 Port
  • PTFE Coated Magnetic Stirrer
  • Visual/Audible

Auto Karl Fischer Titrimeter Product Specifications

  • Aluminium Alloy
  • Up to 50C
  • Automatic Karl Fischer Titrimeter
  • AC Mains
  • Laboratory Analytical Instrument
  • Standard Laboratory Glassware
  • Moisture Content Determination in liquids, powders, solids
  • ABS & MS Powder Coated
  • 230 V AC 10%, 50 Hz
  • For Hospital and Laboratory Use
  • Fischer Titrimeter
  • 340 X 250 X 125 Millimeter (mm)
  • Microcontroller Based
  • No Heating - Ambient Operation
  • 2-5 Kilograms (kg)
  • End Point Auto Detection, Digital Burette, Chemical Resistant, Alarm for End Point, Automated Operation
  • Up to 250 ml Sample Volume
  • 0.01 ml
  • Rectangular
  • 15 W
  • Stirring Speed Adjustable (Up to 1200 rpm)
  • Digital LCD
  • 0.01% to 100% Water Content
  • Volumetric and Coulometric
  • ISO 9001:2015
  • 0.01 ml
  • Liquid, Powder, Solid
  • Platinum Electrodes
  • RS 232 Port
  • PTFE Coated Magnetic Stirrer
  • Visual/Audible

Auto Karl Fischer Titrimeter Trade Information

  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • 7 Piece Per Day
  • 1 Week
  • Australia, North America, Eastern Europe, Middle East, South America, Western Europe, Asia, Central America, Africa
  • All India

Product Description

 Auto Karl Fischer Titrimeter

AJANTA EXPORT INDUSTRIES  are manufacturer, supplier and exporter of Auto Karl Fischer Titrimeter.

Specifications:

Display

Array of 10 LED's in line

Analog Ammeter

Sample Size

1 - 50 mg of water

1 - 50 mg of water

K.F.Dispensing Resolution

0.05 ml.

0.05 ml.

Indication

RUN ADD END
Display in Auto Mode

RUN ADD END
Display in Auto Mode

Detection

Current Sensing by Electronic control

Current Sensing by Electronic control

K.F.Flow

Highly sensitive solenoid control
Volve for automatic control of K.F.Reagent

Highly sensitive solenoid control
Volve for automatic control of K.F.Reagent

Measuring Electrode

Duel Platinum Electrode

Duel Platinum Electrode

Titration Cell

Air tight 200 ml. Glass vessel

Air tight 200 ml. Glass vessel

End Point Delay

30 seconds

30 seconds



Enhanced Moisture Analysis Efficiency

This Automatic Karl Fischer Titrimeter streamlines the process of moisture content determination in diverse sample types, ranging from liquids to powders and solids. Its automated operation, precise digital burette, and easily adjustable stirring speed (up to 1200 rpm) simplify workflow for laboratory professionals, resulting in time savings and enhanced productivity. The inclusion of end-point detection alarms ensures reliable results and operator confidence.


Exceptional Accuracy and Reliability

With a burette resolution and accuracy of 0.01 ml, the instrument delivers dependable and repeatable titration results. Platinum electrodes and chemical-resistant components maintain measurement integrity over prolonged use. The digital LCD allows for clear data visualization, while the robust microcontroller ensures consistent performance in compliance with ISO 9001:2015 quality standards.


Tailored for Modern Laboratory Needs

Designed with the requirements of hospitals and analytical laboratories in mind, the titrimeter offers a compact footprint (340 x 250 x 125 mm) and lightweight construction (2-5 kg). Its RS 232 interface facilitates easy data transfer for documentation or analysis, while the lack of heating and chemical-resistant materials make it ideal for ambient operation with safety and durability.

FAQ's of Auto Karl Fischer Titrimeter:


Q: How does the Auto Karl Fischer Titrimeter determine moisture content in various samples?

A: The device employs Karl Fischer titration, a chemical method that detects and quantifies water content in samples using volumetric or coulometric techniques. The instrument automatically dispenses titrant with high precision and detects the endpoint visually and audibly, ensuring accurate calculations for liquids, powders, and solids.

Q: What types of samples can be analyzed using this instrument?

A: The Auto Karl Fischer Titrimeter is designed to analyze moisture content in a broad range of sample types, including liquids, powders, and solid substances, making it suitable for diverse laboratory applications.

Q: When should this titrimeter be used in laboratory or hospital settings?

A: It is best employed when accurate measurement of trace to high levels of moisture content is required for quality control, research, or process monitoring, especially where compliance with ISO 9001:2015 or similar standards is necessary.

Q: Where can this equipment be installed for optimal use?

A: Due to its compact dimensions and lightweight build, the titrimeter can be conveniently placed on any standard laboratory benchtop in research labs, industrial QA/QC labs, or hospital laboratories throughout India and internationally.

Q: What is the process for operating the titrimeter to analyze a sample?

A: Begin by preparing the sample (up to 250 ml) and loading it into the titration cell. Use the microcontroller interface to set parameters, and the PTFE-coated magnetic stirrer to mix the sample. The automatic burette dispenses titrant while the digital display monitors measurements until the endpoint, which is signaled both visually and audibly.

Q: How does the instrument ensure chemical resistance and durability during use?

A: Constructed from aluminium alloy, with ABS & MS powder-coated components, and fitted with platinum electrodes and a PTFE-coated stirrer, the titrimeter resists corrosion and chemical damage, providing long-term reliability for laboratory and hospital environments.

Q: What benefits does the Auto Karl Fischer Titrimeter offer compared to manual methods?

A: It significantly reduces human error, provides precise and reproducible results, features auto endpoint detection and digital data output, and automates titration for faster and more efficient moisture analysis, supporting robust quality management in analytical workflows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top
trade india member
AJANTA EXPORT INDUSTRIES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.