call-us
Anaerobic Culture Jar With Vacuum Cun Pressure Gauge

Anaerobic Culture Jar With Vacuum Cun Pressure Gauge

3500 INR/Piece

Product Details:

  • Type Anaerobic culture jar
  • Chamber Size 250300 mm internal diameter
  • Chamber Thickness 35 mm stainless steel
  • Outer Size 300 x 330 mm
  • Compressed Air Up to 1.5 kg/cm
  • Door Type Quick release clamp type with central screw
  • Design Pressure Up to 2.0 kg/cm
  • Click to View more
X

Anaerobic Culture Jar With Vacuum Cun Pressure Gauge Price And Quantity

  • 3500 INR/Piece
  • 3500.00 - 4000.00 INR/Piece
  • 1 Piece

Anaerobic Culture Jar With Vacuum Cun Pressure Gauge Product Specifications

  • Quick release clamp type with central screw
  • Up to 50C continuous
  • 300 x 330 mm
  • Approx. 7 kg
  • Ambient to 121C
  • Double-walled, vacuum insulated
  • Variable, recommended 1520 min (with autoclave)
  • Manual gas replacement
  • Removable, holds culture plates/racks
  • 121C (for autoclave compatibility)
  • 1.5 kg/cm max
  • 250300 mm internal diameter
  • Inlet and outlet with control valve and rubber septum
  • 35 mm stainless steel
  • Stainless steel leak-proof connections
  • Pressure/Vacuum gauge integrated
  • Up to 121C if used with autoclave
  • Anaerobic culture jar
  • Up to 2.0 kg/cm
  • Uniform by double-walled construction
  • Not required, for anaerobic culturing
  • Integrated for gas exchange
  • Up to 1.5 kg/cm
  • None (manual operation)
  • Provided for easy movement of jar

Anaerobic Culture Jar With Vacuum Cun Pressure Gauge Trade Information

  • Delhi
  • Telegraphic Transfer (T/T), Paypal, Letter of Credit (L/C)
  • 10 Piece Per Week
  • 4-5 Days
  • Yes
  • If order is confirmed we will reimburse the sample cost
  • Western Europe, Australia, North America, Eastern Europe, Middle East, Central America, South America, Asia, Africa
  • All India
  • ISO, CE, FDA, WHO-GMP

Product Description

Anaerobic Culture Jar With Vacuum Cun Pressure Gauge 

A side arm on the jar is provided for connecting to semi solid locus indicator (The jar is supplied without semi solid locus indicator) with pressure cum vacuum gauge.



Robust Construction and Safety Features

Manufactured using SS 304 or 316 stainless steel, this anaerobic culture jar ensures durability, resistance to corrosion, and safe operation in demanding laboratory environments. The double-walled, vacuum-insulated chamber provides heat uniformity, while a silicone rubber gasket and safety pressure release valve guarantee leak-proof and secure culturing of anaerobic bacteria. All connections are designed with leak-proof piping to prevent accidental exposure.


User-Friendly Design and Versatility

Equipped with detachable components, a quick-release clamp-type lid, integrated pressure/vacuum gauge, and optional transparent observation window, this jar offers flexibility and user convenience. Trolleys for both inside and outside make plate handling and jar movement simple. Compatible with autoclave sterilization (up to 121C), it's suitable for various laboratory procedures and supports routine clinical microbiology applications efficiently.

FAQ's of Anaerobic Culture Jar With Vacuum Cun Pressure Gauge:


Q: How is anaerobic cultivation achieved using this culture jar?

A: Anaerobic cultivation is accomplished by placing Petri dishes inside the jar, sealing it with the silicone rubber gasket and quick-release lid, then evacuating the air and replacing it with an appropriate anaerobic gas mixture using the integrated piping and rubber septum.

Q: What materials make up the jar, and how does this benefit laboratory use?

A: The jar is made from high-grade stainless steel (SS 304/316), offering chemical resistance, long-term durability, and easy cleaning-advantages that support frequent use in microbiology laboratories.

Q: When should the safety release valve be used during operation?

A: The safety pressure release valve should be engaged if the internal pressure exceeds recommended levels (up to 2.0 kg/cm2), or before opening the jar after culturing, ensuring safe handling and preventing sudden release of gases.

Q: Where can this culture jar be utilized?

A: This anaerobic culture jar is suitable for table-top use in laboratories, clinical microbiology departments, educational institutes, and research facilities specializing in anaerobic bacterial cultivation.

Q: What is the process for cleaning the jar after use?

A: All components, including the inner trolley and rack, are detachable. After use, remove these parts and clean them with appropriate disinfectants. The stainless steel construction allows for simple washing and sterilization, including autoclaving up to 121C.

Q: How are pressure and vacuum levels monitored and maintained?

A: A Bourdon type vacuum cum pressure gauge is integrated into the jar to display current internal pressure or vacuum. Inlet and outlet valves, including a rubber septum for manual gas filling or evacuation, allow precise control to maintain required atmospheric conditions for anaerobic bacteria.

Q: What are the primary benefits of using this anaerobic culture jar in a laboratory setting?

A: The jar offers reliable anaerobic conditions, robust safety features, portability, compatibility with autoclave sterilization, easy maintenance, and observation options-streamlining the process of anaerobic culturing while ensuring user safety and operational efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Heat and Refrigeration System' category



Back to top
trade india member
AJANTA EXPORT INDUSTRIES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.