Product Description
We offer karl fischer titremeter that is versatile, compact, rugged & easy to operate instrument to determine moisture contents in liquids & powders. It has auto titration control, auto zero burette, adjustable timer, visual & audible alarm. It display array of 10 led's in line. It indicated run add end display in auto mode. It detct current sensing by electronic control. It has highly sensitive solenoid control volve for automatic control of k. F. Reagent. Its various accessories are burette(clear glass) 10 ml, resorvoir bottle 500 ml, rubber bellow for pumping air, tiration cell 200 ml, dual platinum electrode, PTFE coated magnetic stirring capsule, noozle,moisture trap with rubber tubing.
Accurate Water Content AnalysisThe Karl Fischer Titremeter delivers highly precise determination of water content in a wide variety of substances. Its measuring range spans from 10 ppm to 100%, making it suitable for both trace and high-level moisture analysis in chemicals, oils, pharmaceuticals, and other samples. The 0.2% accuracy, combined with ISO and ASTM compliance, ensures confidence in every result.
Robust and User-Friendly DesignFeaturing a sturdy stainless steel body with powder-coating, the titremeter is chemical resistant and rust proof, designed for intense laboratory use. The integral magnetic stirrer, complete titration glassware, and visually-detected endpoint make it easy to operate and maintain. The rectangular, compact design fits easily onto laboratory benches.
Complete Titration System IncludedThis titremeter comes fully equipped with borosilicate glassware, a platinum electrode, and a precision 10 ml burette, providing all the essentials for immediate volumetric titration. With manual control, users can finely adjust parameters to achieve accurate readings under various sample conditions.
FAQ's of Karl Fischer Titremeter:
Q: How does the Volumetric Karl Fischer Titremeter operate for moisture determination?
A: The instrument uses the classical Karl Fischer titration method in a volumetric format. A sample is introduced into the titration vessel, and a reagent is dispensed from the precision burette. Water in the sample reacts, and the endpoint is visually detected by a color change, assisted by the platinum electrode and built-in magnetic stirrer.
Q: What types of samples can this titremeter analyze?
A: The Karl Fischer Titremeter is suitable for a diverse range of samples including chemicals, pharmaceuticals, oils, and other industrial substances. It can measure water content from trace levels (10 ppm) up to 100%, offering flexibility for most laboratory needs.
Q: When is it recommended to use this instrument in a laboratory setting?
A: It is recommended for routine and rapid water content determination whenever accurate moisture analysis is essential, such as during quality control, product formulation, or research and development phases.
Q: Where should the titremeter be installed for optimal performance?
A: This table-top instrument is best placed on a stable laboratory bench in a dry, dust-free environment. Ensure proper connection to a 220V, 50 Hz single-phase AC mains power supply for safe operation.
Q: What is the process for performing a titration using this device?
A: Place your sample into the provided borosilicate glass titration vessel, set up the magnetic stirrer, and manually add the Karl Fischer reagent using the precision glass burette. Observe for the endpoint indicated by a color change, confirming complete reaction of water in the sample.
Q: What are the key benefits of using the Volumetric Karl Fischer Titremeter?
A: Benefits include high resolution (1 mg H2O), wide measuring range, robust construction, chemical and rust resistance, easy operation, and compliance with ISO and ASTM standards. The manual controls offer flexibility, and the complete assembly allows immediate use upon setup.