Product Description
HORIZONTAL AUTOCLAVE
Most ideal for any institute or laboratory doing bulk sterilizing and research work. This autoclave has double walled chamber and a boiler and these are mounted on a heavy duty mild steel stand. The inner made of thick stainless steel sheet and Outer chamber is made of stainless steel/mild steel sheet. Automatic self closing device to prevent opening of the door while the sterilize is in operation . Stainless steel steam generation unit fitted with easily replaceable heating element. Fitted with Pressure control switch.
| SPECIFICATION:- | HORIZONTAL AUTOCLAVE | |
| SIZE | KILLO-WATT | CAPACITY |
| 300 x 500 mm | 3 KW | 40 ltrs |
| 350 x 550 mm | 4 KW | 50 ltrs. |
| 400 x 600 mm | 5 KW | 78 ltrs. |
| 450 x 600 mm | 5 KW | 98 ltrs. |
| 500 x 750 mm | 6 KW | 152 ltrs. |
| 400 x 1000 mm | 9 KW | 162 ltrs. |
| PRESSURE RANGE | 10 t0 20 psi | |
| | | |
Precision-Controlled SterilizationFeaturing a microprocessor-based digital controller, this autoclave offers customizable sterilization temperatures from 105C to 138C and times up to 999 minutes. The large LED or LCD panel enables easy monitoring, while digital recorders ensure precise documentation of critical parameters. Uniform heating and accurate temperature regulation safeguard both effective sterilization and operator safety.
Robust and Hygienic ConstructionConstructed from high-quality 316/304 grade stainless steel, the autoclave's chamber, piping, baskets, and internal trolleys resist corrosion and ensure sanitation. The exterior can be powder-coated CRCA or stainless steel for enhanced durability. High-density mineral wool insulation minimizes heat loss and optimizes energy consumption.
Advanced Safety and AutomationThe autoclave integrates multiple safety features: over-pressure, over-temperature, and door interlock protection. Automatic or manual water supply, with automatic air removal via vacuum pump, streamlines operation. High-pressure spraying and a silicone rubber gasket further ensure an airtight, safe environment for reliable sterilization.
FAQ's of HORIZONTAL AUTOCLAVE :
Q: How does the horizontal autoclave ensure uniform sterilization throughout the chamber?
A: Uniform sterilization is achieved through precise temperature control (1C at 121C), efficient saturated steam distribution, and high-pressure stainless steel spraying piping. The 316/304 grade stainless steel chamber ensures optimal heat conductivity, while the automatic vacuum system removes air pockets, allowing consistent steam penetration.
Q: What safety features are incorporated in this autoclave model?
A: Multiple safety mechanisms are integrated, including over-pressure and over-temperature protections, a robust door interlock system that prevents opening during operation, safety release and vacuum breaker valves, and high-density mineral wool for thermal insulation. These collectively minimize operational hazards and ensure user and sample safety.
Q: When should the autoclave's sterilization cycles be used in laboratory or hospital settings?
A: The autoclave should be run whenever medical or laboratory instruments, consumables, or waste items require thorough sterilization to eliminate infectious agents. Its adjustable sterilization time (0-999 minutes) and temperature (105C - 138C) settings allow flexibility for various loads and contamination risks.
Q: Where is installation of this horizontal autoclave recommended?
A: Due to its size (outer dimensions: 1730 x 810 x 910 mm) and weight (450 kg), the autoclave is best suited for dedicated sterilization rooms or central processing areas in hospitals, research labs, pharmaceutical facilities, or large-scale clinical laboratories with access to adequate power (220V/380V, 50/60Hz).
Q: What is the process for loading and unloading the autoclave?
A: Operators can use the removable stainless steel inner trolley and 304 stainless steel perforated trays for convenient loading of materials. The horizontal sliding door (manual or automatic) facilitates easy access. After sterilization, the user must wait for pressure and temperature to normalize before safely unloading the items with the inner trolley.
Q: How does the vacuum system enhance the autoclave's performance?
A: The automatic air removal vacuum system eliminates residual air from the chamber prior to and during the sterilization process. This ensures that saturated steam thoroughly contacts all surfaces, maximizing sterilization efficiency and reducing the risk of incomplete processing due to trapped air pockets.
Q: What are the main benefits of choosing this autoclave for laboratory or hospital sterilization needs?
A: Key benefits include high sterilization reliability, advanced safety features, energy efficiency (7 kW power consumption), a user-friendly digital interface, low operating noise, durable stainless steel construction, and versatile design options (built-in/external steam generator, manual/automatic operation) tailored for demanding professional environments.