Product Description
All body made of stainless steel.
Inner Dimension Capacity HeaterLoad
250 x 450 22Litres 3 KW 10 x 18
300 x 375 25Litres 3 KW 12 x 15
300 x 450 30Litres 3 KW 12 x 18
TECHNICAL SPECIFICATION
| Pressure Range | 1.2kgf/cm2 (15 psi) at 121oC |
| Material | Fully Stainless Steel |
| Capacity | 40ltr |
| Temperature Range | 220x230V AC, 50/60 Hz |
INCLUDING
1. Vacuum Breaker
2. Tray
3. Water level indicator
4. Fully automatic PID Purging System
OPTIONAL
A. Vacuum Pump
Superior Stainless Steel ConstructionThis dental autoclave features a fully stainless steel body and piping, providing exceptional corrosion resistance and long-term durability. The cylindrical chamber with a 3 mm thick wall and robust glass wool insulation ensures consistent thermal performance and safety during every cycle.
Manual Control for Reliable OperationEquipped with an analog control system, the autoclave allows precise manual adjustments for temperature and pressure. The intuitive design ensures straightforward operation, making it ideal for dental clinics seeking dependable, hands-on sterilization.
Enhanced Safety FeaturesSafety is prioritized with a mechanical door lock featuring a pressure interlock mechanism. The autoclave incorporates a safety valve and pressure release valve to maintain optimal working and design pressures, thereby keeping users secure during operation.
FAQ's of Fully SS Table Top Dental Autoclave:
Q: How does the manual top filling process work on this dental autoclave?
A: The manual top filling process requires you to open the designated top inlet and pour in the necessary amount of water before starting the sterilization cycle. This ensures the built-in electric steam generator can create steam efficiently for thorough sterilization.
Q: What are the major benefits of using a fully stainless steel construction in this autoclave?
A: Full stainless steel construction provides high resistance to corrosion, easy cleaning, and uncompromised durability, making the autoclave ideal for the demanding hygiene standards in dental clinics.
Q: When should the pressure and temperature settings be adjusted?
A: Pressure (up to 1.2 kg/cm2 working and 2.2 kg/cm2 design) and temperature (121C or 134C) should be adjusted before each sterilization cycle, according to the type of dental instruments and desired sterilization time (15-30 minutes).
Q: Where can this autoclave be installed for optimal operation?
A: The table top design allows installation on any stable, ventilated surface within a dental clinic. It is compact enough to fit in limited spaces while still offering a chamber size of 300 x 300 mm.
Q: What is the process for operating the analog/manual control system?
A: To operate, set the desired temperature and time using the manual dials, ensure proper water filling, and close the single hinged door securely. Monitor sterilization progress with the analog pressure gauge and complete the cycle once the selected parameters are reached.
Q: How can users benefit from the built-in safety features?
A: Users benefit from the mechanical pressure interlock door, safety valve, and pressure release valve, which collectively help prevent accidental opening and regulate chamber pressure, ensuring safe and reliable operation during every cycle.