Product Details:

  • Equipment Type Auto Refractometer
  • Material High-grade plastic housing with internal optical glass components
  • Technology Advanced wavefront analysis and autorefractor technology
  • Properties High precision, non-invasive measurement, digital LCD display
  • Grade Medical grade
  • Lens Specification Compatible with multiple lens types
  • Lens Diameter 2.0 mm 13.0 mm
  • Click to View more
X

Auto refractometer Price And Quantity

  • 1 Piece
  • 150000.00 - 200000.00 INR
  • 150000 INR

Auto refractometer Product Specifications

  • Objective measurement of refractive errors in ophthalmology
  • 275 mm x 475 mm x 480 mm
  • Auto Refractometer
  • Built-in prism measurement
  • High-grade plastic housing with internal optical glass components
  • Approx. 50 VA
  • Advanced wavefront analysis and autorefractor technology
  • Electric/Automatic
  • High precision, non-invasive measurement, digital LCD display
  • Approx. 18 kg
  • Compatible with multiple lens types
  • AC 100240 V, 50/60 Hz
  • Non-sterilized
  • 2.0 mm 13.0 mm
  • Surface wipe with medical disinfectant
  • Medical grade

Auto refractometer Trade Information

  • ambala cantt
  • Paypal, Cash on Delivery (COD), Telegraphic Transfer (T/T), Cheque, Cash Advance (CA)
  • 10 Piece Per Month
  • 7 Days
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • Australia, Central America, North America, Eastern Europe, Western Europe, Middle East, Africa, South America, Asia
  • All India

Product Description

The Auto Refracto meter Matronix Q-30+ from Koria have the function of quick measurement for diopter of 2mm MIN. Pupil siz3 & latest TFT LCD design. With the help of our experienced team members, we have been able to manufacture and supply a wide range of Auto Refracto meter. Technically advance with 1 year warranty and has special IOL feature which enable to take the refractions of post operated patients.

Specifications : -

  • vertical distance : 0mm, 12mm, 13.75mm 
  • Minimum pupil diameter : 02.0mm
  • Charter : Automatic fogging method
  • Power supply : 100~120V/200~240V, 50/60HZ
  • Dimension : 275(W) x 509(D) x 430-460(H)mm
  • Weight : 19kg 


Advanced Technology for Accurate Results

Harnessing wavefront analysis and autorefractor technology, this device delivers high-precision refractive measurements. The auto alignment with real-time tracking ensures consistent accuracy across multiple patients and settings. Its robust measurement range covers a broad spectrum of visual corrections.


User-Friendly Touchscreen Interface

Featuring a high-resolution color touchscreen, the Auto Refractometer offers intuitive navigation for users. The combination of auto and manual measurement modes allows for flexibility, catering to both experienced practitioners and new users alike.


Seamless Data Handling and Patient Comfort

With built-in memory for patient data, a thermal printer, and connectivity via RS-232C and USB, this refractometer streamlines workflow. The motorized chinrest and LED illumination enhance patient comfort and positioning, ensuring a smooth and efficient measurement process.

FAQs of Auto refractometer:


Q: How does the auto alignment and focusing feature enhance the measurement process?

A: The auto alignment with tracking and focusing minimizes user intervention and ensures optimal positioning for accurate readings. This reduces operator error and speeds up the workflow, resulting in consistent and precise measurements.

Q: What types of measurements can this auto refractometer perform?

A: This device measures spherical powers from -25.00D to +22.00D in 0.12/0.25D steps, cylindrical powers from -10.00D to +10.00D, pupil distance (45 mm to 85 mm), prism, and lens diameter (2.0 mm13.0 mm). It also assesses minimum pupil diameters of 2 mm.

Q: When should an auto refractometer be used in clinical practice?

A: An auto refractometer should be used during initial vision assessments, routine eye exams, pre- and post-operative evaluations, and to monitor changes in refractive errors. Its objective measurements provide an essential foundation for prescribing corrective lenses and evaluating changes in vision over time.

Q: Where can the auto refractometer be installed for optimal use?

A: It is suitable for use in ophthalmology clinics, hospitals, optical shops, and mobile eye care units. Its compact design and medical-grade build allow for convenient installation on standard ophthalmic workstations or tables.

Q: What is the process for printing or storing patient data?

A: The built-in thermal printer allows instant hard-copy printouts of results. Additionally, the internal memory stores patient data for later review or transfer via USB or RS-232C interfaces, streamlining patient record management.

Q: How should the device be cleaned and maintained?

A: The auto refractometer is non-sterilized and should be cleaned by wiping the surface with an approved medical disinfectant. Regular external cleaning and periodic internal maintenance ensure optimal performance and patient hygiene.

Q: What are the key benefits of using this advanced auto refractometer?

A: Key benefits include high-precision, non-invasive measurement, fast operation, ease of use via touchscreen, enhanced patient comfort with motorized chinrest, reliable data management, comprehensive compatibility with lens types, and robust, medical-grade construction suitable for diverse ophthalmic environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'ENT Equipment' category



Back to top
trade india member
AJANTA EXPORT INDUSTRIES All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.